1,700 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
180 %
136 %
Prated
10 kW
10 kW
SCOP
4.56
3.48
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.46
3.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4527 kWh
5938 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
180 %
136 %
Prated
10 kW
10 kW
SCOP
4.56
3.48
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.46
3.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4527 kWh
5938 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
180 %
136 %
Prated
10 kW
10 kW
SCOP
4.56
3.48
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.46
3.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4527 kWh
5938 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
180 %
136 %
Prated
10 kW
10 kW
SCOP
4.56
3.48
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.46
3.27
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4527 kWh
5938 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
178 %
135 %
Prated
10 kW
10 kW
SCOP
4.52
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.45
3.27
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4571 kWh
5975 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
178 %
135 %
Prated
10 kW
10 kW
SCOP
4.52
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.45
3.27
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4571 kWh
5975 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
178 %
135 %
Prated
10 kW
10 kW
SCOP
4.52
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.45
3.27
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4571 kWh
5975 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
8 kW
8 kW
El input
1.6 kW
3.08 kW
COP
5
2.6
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
178 %
135 %
Prated
10 kW
10 kW
SCOP
4.52
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
8.9 kW
8.9 kW
COP Tj = -7°C
3.16
2.18
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.45
3.27
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.4 kW
5.2 kW
COP Tj = +7°C
5.63
4.81
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.5 kW
3.6 kW
COP Tj = 12°C
7.89
7.06
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
10 kW
10 kW
COP Tj = Tbiv
2.92
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10 kW
10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.91
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
4571 kWh
5975 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
179 %
135 %
Prated
12 kW
12 kW
SCOP
4.55
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.82
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5453 kWh
7170 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
179 %
135 %
Prated
12 kW
12 kW
SCOP
4.55
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.82
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5453 kWh
7170 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
179 %
135 %
Prated
12 kW
12 kW
SCOP
4.55
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.82
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5453 kWh
7170 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
179 %
135 %
Prated
12 kW
12 kW
SCOP
4.55
3.46
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.46
3.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.82
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5453 kWh
7170 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
177 %
134 %
Prated
12 kW
12 kW
SCOP
4.51
3.44
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.45
3.24
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.8
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5496 kWh
7213 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
177 %
134 %
Prated
12 kW
12 kW
SCOP
4.51
3.44
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.45
3.24
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.8
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5496 kWh
7213 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
177 %
134 %
Prated
12 kW
12 kW
SCOP
4.51
3.44
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.45
3.24
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.8
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5496 kWh
7213 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Heat output
10 kW
10 kW
El input
2.08 kW
3.77 kW
COP
4.8
2.65
EN 14511-4
Shutting off the heat transfer medium flow
caducado
Complete power supply failure
caducado
Defrost test
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
177 %
134 %
Prated
12 kW
12 kW
SCOP
4.51
3.44
Tbiv
-10 °C
-10 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
10.6 kW
10.6 kW
COP Tj = -7°C
2.85
2.14
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
6.5 kW
6.5 kW
COP Tj = +2°C
4.45
3.24
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.6 kW
5.3 kW
COP Tj = +7°C
5.89
4.8
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.4 kW
4.3 kW
COP Tj = 12°C
8
6.94
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
12 kW
12 kW
COP Tj = Tbiv
2.77
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12 kW
12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.87
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricidad
Electricidad
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
5496 kWh
7213 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Declared load profile
L
Efficiency ηDHW
148 %
COP
3.49
Heating up time
01:47 h:min
Standby power input
36 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l