Ecodan Power Inverter 10-300D AA
Heat Pump Type: Outdoor Air/Water
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.20 kW
11.20 kW
El input
2.51 kW
4.13 kW
COP
4.46
2.71
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
132 %
Prated
10.60 kW
10.00 kW
SCOP
4.32
3.37
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
9.40 kW
8.90 kW
COP Tj = -7°C
2.75
1.95
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
5.70 kW
5.40 kW
COP Tj = +2°C
4.21
3.22
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.50 kW
4.70 kW
COP Tj = +7°C
5.55
4.79
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.30 kW
5.30 kW
COP Tj = 12°C
7.47
6.12
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
9.40 kW
8.90 kW
COP Tj = Tbiv
2.75
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.55 kW
9.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.80
1.80
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.40 kW
Annual energy consumption Qhe
5026 kWh
6089 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
120 %
COP
2.90
Heating up time
03:41 h:min
Standby power input
41.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l